Ventilation – Things to Consider

Nick Higgs of Elta Trade joins Aaron Worrall to explain why fitting an extractor fan isn't enough on its own, and how design, positioning, installation and commissioning determine whether a ventilation system actually works.

Episode
No. 6
Published
Length
1 hr 18 min
Guest
Nick Higgs, Elta Trade

This episode on

About this episode

Ventilation is one of the most important and most misunderstood parts of creating a healthy home. Aaron Worrall is joined by Nick Higgs of Elta Trade, who has spent almost 15 years in residential ventilation, to ask the questions homeowners are afraid to. Nick’s central point runs through the whole conversation: fitting a fan is not the same as ventilating a property properly.

It is worth bearing in mind who is talking. Elta is a manufacturer of ventilation products, and Aaron says Weatherwise buys and uses its fans, so Nick has an interest in the equipment he recommends. Much of what he says, though, is about how any system is chosen, installed and used.

Why airtight homes need more ventilation, not less

Nick says people take ventilation for granted because air is free, until a problem shows up. Older houses, he says, were leaky and so healthy: they had chimneys that let air flow through, and gaps that let moisture out. Then gas came in and chimneys were sealed, and old timber windows were replaced with sealed uPVC windows and doors. Trickle vents went into wet rooms and not bedrooms, where they should be, and he calls that a big catalyst for the problems seen today. The window industry and the ventilation industry, he says, hardly talk to each other.

Fans, trickle vents and short-circuiting

A fan can only extract air if replacement air can get in. Nick’s example is his own house, where an extractor fan sits only a short distance from a window with a trickle vent, so the air bypasses the room. A wet room with an extractor fan should not also have a trickle vent beside it, he says.

In a well-planned system the extract is in the bathroom, and supply air comes into habitable rooms through trickle vents or a ducted unit. Door undercuts matter as well: he says you need about 10 mm under all your doors so air can move from room to room when they are closed.

Continuous versus intermittent extraction

Nick says the first step for anyone with condensation and mould is a continuously running fan. It runs at a low rate and keeps the air moving, so warm, moist air does not sit against colder surfaces and condense. By his account the continuous rates are small: a kitchen needs a minimum of 13 litres a second, a bathroom or utility 8, and a WC 6. An intermittent fan boosts on maximum when you are in the room, which is where noise complaints come from, but it only runs for a short time, and once it switches off the water vapour is still there.

Continuous fans, he says, are very energy efficient and cheap to run, and he has four at home with no visible difference in his bills. He says they have come a long way in noise and looks, and that he can barely hear his own. The practical warning is about the isolator switch, often above the door: people turn fans off, forget to turn them back on, and the problems return. He also recommends cleaning them every couple of months, because a fan pulls in a surprising amount of dust.

Where installations go wrong

Much of the conversation is about installation. Nick says he spends half his time in lofts and sees the same faults again and again. Fans are fitted to wet rooms with ducting that does not go outside, or with no ducting at all. Flexible ducting, which he calls devil duct, is coiled so that water sits in it, or looped over a joist and dripping onto the insulation. He would like it banned and says the regulations now limit it to a short final connection; where it is used it should be strapped to prevent moisture pooling.

He also says many fans are set up wrongly, because nobody understood them or tested them. The setting depends on occupancy and how much vapour there is. For MVHR an airflow meter is always used, because the flows in each room have to be recorded, but for individual fans he would struggle to count how often it is done. Most of the calls he gets about fans not working, he says, trace back to a fan that was never measured.

Part F and what is changing

Part F of the Building Regulations covers ventilation, and Nick says it has changed several times. The airflow rates have changed little. What has changed is the push towards making people accountable for design, installation and commissioning, so that what is designed is what is achieved on site, including pressure drops. Part F is guidance, he stresses: the wording can be woolly, interpretation varies, and whether it is policed is a grey area, though he thinks it is moving in the right direction. Intermittent fans are still an option, but the rules push towards continuous ventilation and he calls intermittent fans a dying breed.

Competence is his biggest frustration. Electricians and gas engineers go through long courses, he says, whereas ventilation training can be two or three days, and plenty of people have an electrician fit a fan without the right qualification. He would also like building control officers to be better educated, since they sign the work off, and for commissioning certificates to be taken seriously. On Awaab’s Law, Nick says it has changed a lot about how things should be done, though he doubts it has yet changed what is done: he says a recent report found people attending on time but doing the bare minimum, such as cleaning, rather than finding the root cause.

MVHR and decentralised options

Nick calls MVHR the gold standard of residential ventilation. A single unit holds two fans, two filters and a heat exchanger, with ducting to every room. It extracts from wet rooms and supplies filtered air to habitable rooms, replacing local fans and trickle vents, and runs continuously at a low background rate. The heat exchanger passes heat, not moisture, from the outgoing air to the incoming air; he puts typical heat recovery at 85 to 90 per cent. Filters need changing at least once a year, and the heat exchanger needs an occasional clean. The main downside is the capital and installation cost.

In an existing home he says decentralised fans are a fantastic alternative: cheaper to install and maintain, with similar benefits apart from the heat recovery. A single-room heat recovery unit can add some of that, though not the same filtration or heat recovery as a whole-house system. For the right budget he would build a solution down from the gold standard, and a positive input ventilation unit plus decentralised fans, which Aaron says he has at home, can give fabulous results. Given the choice in a new build, Nick says, he would go nowhere other than whole-house MVHR.

Heating, humidity and habits

Relative humidity depends on temperature, and Nick uses glasses to explain it. A cold room is a shot glass, a mid-sized room a half-pint glass and a warm room a pint glass. The same amount of water fills the small glass much sooner, and it overspills, which is condensation. With energy costs as they are, he says, people turn the heating down and see more condensation and mould as a result, and keeping a house at a steadier temperature carries more moisture so there is less to condense. Dry air is also easier and cheaper to heat than wet air, he says, using the image of a cold bucket of water and a wet blanket. He adds that air can also be too dry.

Habits matter too. Dry washing in a room with a fan, not on radiators on external walls, and open a window after a shower. Once a house has the right ventilation and is working, Nick says, the owner can within reason live as they like. His own habits have not changed since he put the right strategy in; the one habit that must change is turning the fans off.

When ventilation needs change

A question Nick hears often is why a home that never had mould now has some. He asks what has changed. A baby brings boiling, bathing and washing; working from home means more moisture produced during the day; and, as he says, anything living produces moisture, including pets. He tells of a customer with mould who lived alone with 15 cats. Add new windows, doors or insulation, and a home’s old ventilation no longer copes. He also warns about loft insulation moved aside to wire a light and never put back, which leaves a cold spot.

Dehumidifiers

Asked about dehumidifiers, Nick says the best one is your back door. If someone cannot afford better ventilation but can afford a dehumidifier, though, he says that is better than doing nothing, provided they know the longer-term fix is better ventilation. He is not promoting dehumidifier sales. Aaron adds that they are expensive to run.

Fix it before the season starts

Condensation season begins at the end of September and in October, Nick says, and enquiries take off like a rocket, while Aaron says surveys are booked weeks ahead. Lead times and stock get tighter as demand rises. His advice is to be proactive: if you suffered last winter, deal with it in the warmer months, when it is easier, less intrusive and quicker to get an installer and stock.

The Healthy House Checklist

Nick’s three points are supply air, extract air and habits. First, check your extractor fans: are they there, working, clean, the right size and moving the right amount of air, and when do they come on and go off? Second, check the makeup air: are your trickle vents clean, open and clear? Third, look at your habits: do not turn your fans off, dry clothes in rooms with fans and not on external-wall radiators, and open a window after a shower, because even with a fan you still need to help it. If an extractor is not performing, a good first step is to get it tested with an airflow meter and replaced if it is not up to scratch, then consider a continuous strategy.

Who should listen

This episode is for homeowners, landlords, builders and property professionals who want to understand how effective ventilation reduces condensation and supports a healthier home, particularly anyone who has recently upgraded windows, doors or insulation and wants to know how their home now needs to be ventilated.

Questions this episode answers

Why do I still get condensation when I have extractor fans?

A fan on its own does not guarantee good ventilation, says Nick Higgs. The right size for the room, its position, the installation and the commissioning all matter. Common faults include a trickle vent right beside the fan, so air short-circuits instead of crossing the room; flexible ducting that holds water; ducting that does not reach outside; and a fan that was never set up or measured. He also says a fan that is old or never cleaned can still run but move far less air.

Should my extractor fan run all the time?

Nick Higgs says yes: a continuously running fan is the first step if you have condensation and mould. It runs at a low rate and keeps the air moving, so warm moist air does not sit against cold surfaces, whereas an intermittent fan only works while it is on and leaves water vapour behind when it stops. He says continuous fans are very cheap to run, that he has four at home and cannot see a difference in his bills, and that people should never switch them off at the isolator. Clean them regularly, he adds, every couple of months, because they pull in a lot of dust.

What is the difference between MVHR and dMEV?

Nick Higgs explains that decentralised mechanical extract ventilation (dMEV) uses a continuously running fan local to each wet room, venting through the wall or roof, while MVHR (mechanical ventilation with heat recovery) is a single centralised unit that ducts air to and from every room. An MVHR unit has two fans, two filters and a heat exchanger: it extracts from wet rooms, supplies filtered air to habitable rooms, and passes heat, not moisture, from the outgoing air to the incoming air. He calls it the gold standard and says typical heat recovery is 85 to 90 per cent.

Why do trickle vents matter, and where should they go?

An extractor fan can only remove air if replacement air is able to come in, and Nick Higgs says trickle vents in habitable rooms, particularly bedrooms, are the traditional way to provide it. His point is that a wet room with an extractor fan should not have a trickle vent right next to it, because the air bypasses the room. He says that many window installs put trickle vents in wet rooms and not bedrooms, and that the window and ventilation industries rarely talk to each other. Gaps under internal doors, he says, about 10 mm, let air move between rooms.

Why has mould appeared in my home when I have lived here for years?

Nick Higgs says the first question he asks is what has changed. A baby means more boiling, bathing and washing; working from home means more time spent producing moisture; and anything living, including pets, gives off moisture. New windows, doors and insulation can also make a home airtight so that its old ventilation no longer copes. Aaron's way of putting it, which Nick agrees with, is to extract the moisture from the small bucket that is your house and put it in the big bucket outside.

What does Part F of the Building Regulations say about ventilation?

Nick Higgs says the airflow requirements in Part F have not changed much; what has changed is the push towards accountability for the design, installation and commissioning of ventilation, including pressure drops and measuring on site. The regulations are also steering people towards continuous strategies: intermittent fans are still allowed but, he says, are a dying breed. He adds that Part F is guidance, its wording can be woolly, and how well it is policed is a grey area. Volume one covers dwellings and volume two non-residential buildings.

What goes wrong with extractor fan installations?

Nick Higgs says the most common problems are fans that were not set up for the occupancy and never tested, and loft ducting problems. He describes coiled flexible ducting with water sitting in it, ducting looped over a joist and dripping onto insulation, and fans fitted to a wet room with ducting that does not go outside, or no ducting at all. He would like flexible 'devil duct' banned, saying the regulations now limit it to a short final connection, and says too many people have their electrician fit a fan without the right qualification. He says he would struggle to count how often an airflow meter is used on an individual fan, though MVHR requires one.

Do I need a dehumidifier?

Nick Higgs jokes that the best dehumidifier is your back door. He says improved ventilation is the better fix, but if someone cannot afford that and can afford a dehumidifier, it is better than doing nothing, as long as they know the longer-term plan should be to improve the ventilation. Aaron Worrall adds that people often do not realise how expensive dehumidifiers are to run.

Can MVHR be fitted to an existing home?

Yes, says Nick Higgs, who has done a number of retrofit installations. It depends on where the unit can go and where the ducting can run. If the whole house is not practical, a hybrid is possible: for example MVHR serving the first floor from the loft, and decentralised fans downstairs. He adds that bedrooms are often the biggest source of condensation, because that is where people are asleep and breathing out moisture.

Who is Nick Higgs?

Nick Higgs of Elta Trade had been in residential ventilation for almost 15 years, and at Elta Trade for nearly two, when the episode was recorded. He is the guest on Episode 6 of The Healthy House Podcast, where he explains why fitting a fan is not enough and how design, positioning, installation and commissioning decide whether a ventilation system works. Elta is a manufacturer of ventilation products.